- AED Per Default, Reliable For Any BLS Rescuer, Can Be Easily
Switched In a Manual Defibrillator Giving To ALS Responders The
Best Decision-Making Control For a Manual Shock Timing or An
Electric Cardioversion (Synchronised Shock).
Defibrillator:
-
Operation: AED Semi-Automatic (default) ECG Monitoring
-Manual Asynchronous or Synchronous (used to convert atrial or ventricular tachyarrhythmias). - Energies: Standard max 200J or Power max 360J
-
Waveform: Adaptive BTE (biphasic truncated exponential)
conforming to patient chest’s impedance. - Energy type: Escalating from 50 to 360J
-
AED Protocols: Adult Standard escalating 150, 200, 200J
Adult Power escalating 200, 250, 360J
Pediatric (Standard or Power) 50J fixed
(AED adult shock protocols can be customized). - Manual Protocol:Selected by users from 50 to 360J. For electric cardioversion (in Synchronous mode) the shock is synchronised to occur with the R wave of the ECG.
-
Energy Display: Screen provides the energy to deliver both in
Manual mode or AED mode. -
Charging time:≤9 seconds with a new and fully charged battery
depleted battery will result in a longer charging time. - Analysis time: IEC/EN 60601-2-4 from 4 to 15 seconds
- Impedance: 20-200 ohms
- Sensitivity: IEC/EN 60601-2-4 (AHADB, MITDB source), 97%
- Specificity: IEC/EN 60601-2-4 (AHADB, MITDB source), 99%
-
Controls: 2 buttons: ON/OFF, shock button;
3 buttons: to surf the menu;
3 buttons: select energy, charge, disarm the device -
Indicators: Status LED indicator informing on device condition
Battery gauge with remaining capacity rate
Audible alerts and text display with service alarms. - Upgradeable: through a USB cable or memory card.
ECG Monitoring:
-
Operations: Through defibrillation pads or standard ECG
electrodes attached to a separate 2-Lead patient
monitoring reusable cable SAV-C0017. - ECG size: Manual setting through the menu.
- Heart Rate: 30-200 bpm.
- Sweep Speed: 25 mm/sec.
-
Standard: IEC/EN 60601-2-27 less then the points 202.6.2.101;
201.12.1.101.12,13; 208.6.6.2.101 not performed for the
intended use of the device,as it is not intended for
environments such as operating theatres
or intensive care units. - Display: 5,7” TFT colour, 640 x 480 pixel.
Battery options:
- Type: Li-SOCl2 Disposable, code SAV-C0903
-
Autonomy: 250 complete rescue cycles (shocks at 200J and CPR) or
160 complete rescue cycles (shocks at 360J and CPR) or
24 hours ECG Monitoring for a new and fully charged
battery (*). - Shelf-Life: when stored in original packaging 5 years (*).
-
Battery-Life: 4 years once installed to AED, assuming one battery insertion
test and daily self-test but without switching AED on (*). - Type: Li-ion Accumulator, code SAV-C0011.
-
Recharging time: 2,5 hours with the charger station code SAV-C0014 (*)
(recommended to charge every 4 months at least). -
Autonomy: 200 shocks at 200J or 110 shocks at 360J or 14 hours in
ECG Monitoring for a new fully charged accumulator (*). - Battery-Life: 2 years or 300 charging cycles (*).
Pads options:
- Type: Disposable, pre-gelled and self-adhesive
- Adult: Code SAV-C0846, for patient >8 years or >25 kg.
- Pediatric: Code SAV-C0016, for patient <8 years or <25 kg.
- Cable length: 120 cm.
- Shelf-Life: 30 months.
Event recording:
- Internal memory: up to 6 continuous hours of ECG and rescue events.
-
Optional memory: Removable SD card; length of storage depends on card
capacity: a 2GB card records up to 100 hours. -
Data recording: “AED1LOG“ text file with detailed self-test activity
“AEDFILES“ with complete recorded information. - Event review: “Saver View Express“ data manager software.
Physical:
- Size: 26,5 x 21,5 x 7,5 cm.
-
Weight: 2,08 kg with disposable battery and pads
2,13 kg with rechargeable battery and pads.
Environmental:
- Operating temperature: 0°C to 55°C (32°F TO 131°F)
- Storing/Shipping temperature: -40°C to 70°C (-40°F TO 158°F) without battery.
- Humidity: 10% to 95% relative humidity non condensing.
- Sealing (IP Protection): IEC/EN 60529 class IP54;splash proof, dust protected.
-
Shock/Drop Abuse Endurance: IEC/EN 60601-1 clause 21; 1 meter drop, impact,
force, rough handling, mobile tolerance. -
Electrostatic Discharge: IEC/EN 61000-4-2
-
Electromagnetic Compatibility: IEC/EN 60601-1-2 Emission, Immunity
-
Electrical Protection: IEC/EN 60601-1; Internally Powered Type BF/CF
Directive93/42/CEE and 2007/47/CE: Class IIb
Lead time:
Our lead times are 5-7 working days excluding weekends, public holiday’s & shipping time with our courier.
Lead times on out of stock or special-order items 6-8 weeks / 8-10 weeks
PLEASE NOTE DUE TO UNFORSEEN ROAD OR AIR FREIGHT DELAYS PARCELS CAN BE DELAYED BY A FEW DAYS.
*Please note pictures are mainly for illustration purposes, actual product and size may vary slightly*